高纯有机试剂中金属杂质OSIS-ICP-MS测试方法

2735    2016-01-16

免费

全文售价

作者:谭和平, 吕昊, 张玉兰, 王顾希, 孙羽婕, 陈能武

作者单位:中国测试技术研究院, 四川 成都 610021


关键词:有机试剂; 金属; 电感耦合等离子体质谱法; 测试


摘要:

建立有机进样系统-电感耦合等离子体质谱法(OSIS-ICP-MS)直接测试高纯有机试剂中金属杂质。高纯有机试剂直接由有机进样系统(OSIS)导入质谱仪进行分析,可有效避免样品处理可能带来的污染和误差。与传统方法比较,该文所建立的方法准确、快速、灵敏、环保,并兼顾成本,具有良好的推广应用前景。


Determination of metal impurities in high-purity organic reagents by OSIS-ICP-MS

TAN He-ping, LÜ Hao, ZHANG Yu-lan, WANG Gu-xi, SUN Yu-jie, CHEN Neng-wu

National Institute of Measurement and Testing Technology, Chengdu 610021, China

Abstract: An OSIS-ICP-MS method was established to directly and rapidly determine metal impurities in high-purity organic reagents. Organic reagents can be introduced into ICP-MS system directly without any treatment, and potential contaminations and errors coming from sample treatment can be avoided as possible as it may accordingly. Comparison with routing method proved that the developed method could be addressed as accurate, environmental friendly, rapid, sensitive and inexpensive method, and be worth of widely application.

Keywords: organic reagent; metal; ICP-MS; determination

2013, 39(2): 30-33  收稿日期: 2012-9-12;收到修改稿日期: 2012-10-29

基金项目: 国家科技支撑计划项目(2009BAK61B04)(2012BAK25B00)质检公益性行业科研专项(201310240)

作者简介: 谭和平(1957-),男,重庆市人,研究员,享受国务院政府津贴专家,从事生物化学研究。

参考文献

[1] 徐志方,张鸿翔,刘丛强,等. 有机试剂雾化进样电感耦合等离子体原子发射光谱特性的研究[J]. 分析化学,2000, 10(1):273-277.
[2] 全灿,鄢雄伟. 科研用高纯乙醇、乙酸乙酯、正己烷试剂标准规范及其纯化工艺研究进展[J]. 化学试剂,2011,33(5):385-392.
[3] ISO 14453-1997 Pulps-Determination of acetone-soluble matter[S].
[4] SEMI C19-0708-2008 Specification for acetone[S].
[5] SEMI C19-0301-1999 Specification for acetone[S].
[6] JIS K 8034-2006 Acetone[S].
[7] JIS K 1503-2009 Acetone[S].
[8] SH/T 1627.1-1996工业用乙腈[S].
[9] DB 34/T 1404-2011高纯试剂 乙腈[S].
[10] JIS K 8102-1994 Ethanol[S].
[11] DB 34/T 1403-2011高纯试剂乙醇[S].