摘要:

针对传统的基于ADC的应变测量系统具有高功耗、精度低、抗干扰性差、成本高等缺点的情况,设计一种基于TDC(时间数字转换)芯片PS081的无线应变测量方案,只需要一颗PS081芯片即可实现应变信号到数字信号的转换。文章详细描述了测量电路的基本原理和具体实现方法,并与ADC应变采集方案进行对比,通过对比表明:该方案具有低功耗、高精度、宽测量范围、不需调零、抗干扰性好、体积小等特点。


Hardware design of PS081-based wireless strain measurement system

DENG Fei, HU Chi, GUAN Mingyang

Institute of Computer Applications, China Academy of Engineering Physics, Mianyang 621900, China

Abstract: In order to solve the probelms of tranditional measurement system based on ADC, for examples, advantages of high-power, low-precision, big disturbance, High-cost, A wireless strain measurement system based on a TDC (Time to Digital Converter) chip PS081 was designed in this paper. The scheme only need to realize the conversion of strain signal to digital signal to a PS081 chip. The basic principles of the measuring circuit and specific implementation are described in details. A comparison was made between TDC and ADC strain measurement, and the result shows the system designed in this paper has the advantages of low-power, high-precision, wide measuring range, no zeroing, anti-interference and small size.

Keywords: TDC;wireless strain measurement;ARM;PS081

2015, 41(5): 103-106  收稿日期: 2014-8-19;收到修改稿日期: 2014-10-27

基金项目: 

作者简介: 邓霏(1988-),男,四川绵阳市人,工程师,研究方向为软件测试、智能仪器与传感器。

参考文献

[1] Wang D W, Wang H, Liang Z G, et al. Study of eliminating calculation errors in large-strain measurement with strain gauges[J]. Applied Mechanics and Materials,2011(9):138-139.
[2] Sensmeier, Mark D, Nicho, et al. Minimizing vibratory strain measurement error[J]. American Society of Mechanical Engineers,1998(34):72-78.
[3] 张兆亭,闫连山,王平,等. 基于光纤光栅的钢轨应变测量关键技术研究[J]. 铁道学报,2012,34(5):65-69.
[4] Jian G D, Guo B S, Song Q L. A high-resolution time-todigital converter system based on digital delay line[J]. Nuclear Techniques,2005(15):37-40.
[5] 吕凡任,邵红才,金耀华,等. 真压力对电阻应变片应变测量影响的实验研究[J]. 工业建筑,2012,43(6):98-101.
[6] 国海东,姜丽娟. 数字式静态应变测量试验系统的设计[J].吉林化工学院学报,2010,27(4):55-58.
[7] 张博. 用CP2102升级串行接口为USB接口的应用设计[J].自动化技术与应用,2009,28(6):101-105.